Alloy Master Links

Alloy Master Links

  • Alloy Steel Quenched and Tempered.
  • Individually proof tested to values shown, with certification.
  • Proof tested with fixture sized to prevent localized point loading per ASTM A952.
  • Proof test certification shipped with each link.
  • Sizes from 1/2" to 2" are drop forged and have a Product Identification Code (PIC) for material traceability, along with the size and the name Crosby and USA in raised lettering.
Specifications
SIZE "A" (IN.) WORKING LOAD LIMIT (LBS.) PROOF LOAD (LBS.) WEIGHT EACH (LBS.) DIMENSIONS
Inside Width
Inside Length
DEFORMATION INDICATOR
1/2 7000 14000 .82 2.50 5.00 3.00
5/8 9000 18000 1.52 3.00 6.00 3.50
3/4 12300 28400 2.07 2.75 5.50 3.50
7/8 15000 30000 3.50 3.75 6.38 4.50
1 24360 48700 4.85 3.50 7.00 4.50
1-1/4 36200 72400 9.57 4.38 8.75 5.50
1-1/2 54300 113200 16.22 5.25 10.50 6.50
1-3/4 84900 169800 25.22 6.00 12.00 7.50
2 102600 205200 37.04 7.00 14.00 9.00
2-1/4 143100 289200 54.10 8.00 16.00 -
2-1/2 160000 320000 67.75 8.00 16.00 -
2-3/4 216900 433800 87.70 9.50 16.00 -
3 228000 456000 115.00 9.00 18.00 -
3-1/4 262200 524400 145.00 10.00 20.00 -
3-1/2 279000 558000 200.00 12.00 24.00 -
3-3/4 336000 672000 198.00 10.00 20.00 -
4 373000 746000 228.00 10.00 20.00 -
4-1/4 354000 708000 302.00 12.00 24.00 -
4-1/2 360000 720000 345.00 14.00 28.00 -
4-3/4 389000 778000 436.00 14.00 28.00 -
5 395000 790000 516.00 15.00 30.00 -
*  Minimum Ultimate Load is 5 times Working Load Limit. Based on single leg sling (in-line load), or resultant load on     multiple legs with an included angle less than or equal to 120 degrees. 
** Proof test load equals or exceeds the requirement of ASTM A952(8.1) and ASME B30.9-1.4 for the chain size and number of legs.
Welded  Master Link.
www.johnsakash.com Illinois
700 Walnut Street
Elmhurst, IL 60126
Phone: 630-833-3940 800-929-3940
Fax: 630-833-9830
Indiana
7945 Nevada Street
Hammond, IN 46320
Phone: 219-989-1000
Fax: 219-989-1100